Dental Autoclave Sterilizer, 4.3’’ Colour Screen, Fully Automatic Autoclave Machine For Dental Clinic, 18L/23L

Istar Dental SupplySKU: QD-AC-02-1

Volume: 18L
Price:
Sale price$2,288.00
Chat on WhatsApp
Free Shipping
United States: in 5-15 days. 0ther Countries: in 15-20 days.
Return & Refund
Returnable within 30 days for return or refund.
Free Registration
Sign up and get 5% off your first order.
Warranty Time
The warranty period for our dental equipment is 6 months

Description

Features:

4.3 inch TFT colour screen

Precise touch screen control, simple, innovative and practical.

Intelligent monitoring and diagnosis system

Real-time monitoring of the entire sterilization operating system. Once a fault occurs, the intelligent diagnosis system can find the faulty parts in sections, and can directly retrieve the fault information and simple solutions, so that the repair accuracy reaches 100%, making maintenance more convenient. This intelligent diagnosis system is like a "real technical character" with real-time diagnosis and intervention capabilities.

Good traceability

Standard large-capacity storage to realize automatic storage and retrieval of sterilization data. An optional external thermal printer can automatically print the sterilization data and sterilization results after each sterilization program is completed.

Preheating system

The preheating standby function keeps the temperature above the minimum temperature at all times, making the program run faster and more energy-efficient.

Super large air-conditioning heat dissipation window

260x142mm open heat storage, strong power, 73 layers of heat dissipation aluminum plate and 18 heat dissipation pipes, efficient condensation, ensure that hot water is instantly cooled to normal, and protect the drainage channel.

Quick drainage system

The imported quick interface, located at the front of the sterilizer, makes the work of adding water and draining water extremely simple and fast. Moreover, the water gate is automatically discharged directly, which effectively prevents the pollution of the internal water system of the chrysanthemum destroyer. Not only that, it can also be equipped with an automatic water filling system to realize automatic water supply from the external water tank.

Futuristic handle

Give you a different visual experience, enjoy the technology comfortably.

Built-in open water tank

The 3.5L large-capacity water tank can meet the water needs of 5 sterilization cycles. The fully open water tank can be monitored and easily cleaned. It is easy to check the water quality in the tank and facilitate daily cleaning and disinfection.

Parameter:

Applicable voltage

220-240 VAC-50/60Hz, single-phase voltage

Rated voltage

220V, 50Hz

Maximum current

10A

Maximum altitude

Altitude 2000 meters

Maximum working pressure

2.5 Bar(250 kPa)

Minimum working pressure

-0.9 Bar(-90 kpa)

Minimum atmospheric pressure

0.7bar

Maximum temperature

<145°C

Dimensions

585x438x405mm(Novo Pro 18L)

685x438x405mm(Novo Pro 23L)

Full load weight

50 kg(Novo Pro 18L)

60kg(Novo Pro 23L)

Safety threshold

2.45 bar (compliant with YY0154-2013 and YY/T0157-2013)

Vacuum degree

>-0.08Mpa

Noise level

<80 DB

Total volume of the pot

245 mm xD355 mm(Novo Pro 18L)

245 mmxD445 mm(Novo Pro 23L)

Usable pot volume

198 mmx204mmx319mm(Novo Pro 18L)

198 mmx204mmx385mm(Novo Pro 23L)

Steam filter

Filtration efficiency of particles above 0.3μm is not less than 99.5%

Water quality requirements

EC(conductivity <15uS/cm)

Average water consumption per cycle

Novo Pro 18L:0.15L(minimum) 0.26L(maximum)

Novo Pro 23L:0.17L(minimum)0.31L(maximum)

Water tank volume

Water tank 3.5L

Procedures

Load Types

Sterilization Type

Temperature ()

Sterilization Time (Minutes)

Drying Time (Minutes)

Solid Instruments

Solid Instruments

S

134/121

10/30

9

Rapid Sterilization

Emergency Sterilization Of Bare Instruments/Rubber

S

134/121

4/20

4

Porous Instruments

Solid And Hollow Loads, Cotton Ball Fabric

B

134/121

5/20

18

Wrapped Instruments

Cotton Ball Fabric, Wrapped Instruments, Hollow Loads

B

134/121

18/30

18

 Precautions:

1. Do not add any water with chemical or similar ingredients to the steriliser.
2. Do not sterilise volatile substances, toxic materials or other unsuitable equipment.
3. Do not place the steriliser in direct sunlight.
4. Do not place the steriliser on heat sensitive surfaces.
5. Cleaning with unsuitable materials.
6. Misuse the steriliser.
7. Use the steriliser in an area where it is likely to come into contact with flammable materials or gases.
8. In order to ensure the quality of sterilisation of instruments after 6 months of use or 200 cycles of operation, please replace the air filter in a timely manner.

Troubleshooting:

Error Code

Cause Of Error

LCD Prompt Message

Solution

CODE1

The pressure did not reach the set value after heating up and boosting for 30 minutes

Error: 01 Slow heating

1. Steam generator is damaged

2. Severe air leakage in the cabin door

3. The balance valve is incorrectly opened

4. The drainage valve is incorrectly started

5. The voltage is seriously low

CODE2

In the process of heating up or sterilization, the pressure is greater than the set pressure

Error: 02 Too much pressure

1. The internal temperature sensor is faulty

2. The vacuum pump is faulty

3. The solenoid valve leaks
Altitude setting error

CODE3

Door opening detected during operation

Error: 03 Door lock is open

1. Door lock switch is not good

2. Clearance between hatch and pan body

CODE4

The pressure is less than the set pressure in the process of heating up or sterilization

Error: 04 Pressure is too low

1. The internal temperature sensor is faulty

2. The solenoid valve leaks
Altitude setting error

CODE5

In the vacuum process, the exhaust within 20 minutes (the first vacuum is 30 minutes) failed to reach 20kpa, and the exhaust failed to reach 20kpa in 25 minutes after the completion of sterilization

Error: 05 Abnormal pressure relief

1. The altitude setting is incorrect

2. The pipe is blocked
Defective solenoid valve

CODE6

The vacuum process failed to reach -0.4bar for 5 minutes, and the leak test failed to reach -0.6bar

Error: 06 Slow vacuum speed

1. Poor seal

2. The vacuum pump is faulty

3. The altitude setting is incorrect

4. Defective solenoid valve

CODE7

Ambient atmospheric pressure < 0.7bar was detected

Error: 07 Low ambient pressure

1. The altitude setting is incorrect

2. Pressure sensor failure

CODE8

Door lock switch logic detection error

Error: 08 Door opening error

1. The door opening switch is broken

2. Poor motor

CODE9

Motor running error

Error: 09 Closed the door incorrectly

1. The door close switch is broken

2. Poor motor

CODE10

Preheat for 20 minutes, the wall temperature < 100 degrees Celsius, the generator temperature < 110 degrees Celsius

Error: 10 Full preheat

1. Bad steam generator

2. Bad heater

CODE11

The temperature exceeds the theoretical +2 degrees or exceeds the maximum required by the specification during the heating and pressure boost or sterilization process

Error: 12 The temperature is too high

1.The internal temperature sensor is faulty

2. The voltage is abnormal

3. The vacuum pump is faulty

4. Solenoid valve leakage

CODE12

In the process of heating up or sterilization, the temperature is lower than the theoretical temperature of -2 degrees or exceeds the minimum required by the specification

Error: 12 The temperature is too low

1. The internal temperature sensor is faulty

2. Voltage anomaly

CODE13

Add water more than 3 minutes for low water level, or less than 4.5 minutes

Error: 13 The time for adding water exceeds the limit

1. The water pump is damaged

2. The water level switch is broken

3. The device does not support automatic water addition

4. Check the configuration bit

 

Payment & Security

Visa Mastercard American Express PayPal Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

All of our products come with free shipping, so please don't worry about shipping.

We have put a lot of focus on making sure the items get delivered to our customers as quickly as possible.

The total time is the sum of the processing time and the shipping time. Processing time = the time between when you place an order and when we ship it; Shipping time = the time between when your order has been shipped and deliveto you;

All products have a 1 day processing time

For most products, processing time is 1 day and shipping time is 7-20 days.
In the United States it usually takes 7-15 business days to receive your order; in other countries it can take up to 15-20 days to receive your order.

For large dental equipment, such as dental chairs, the processing time is 1-3 days and shipping time is usually 30-40 days.

All of this information is described inside the product details, if you would like to confirm a more precise time, please contact us and we will calculate it for you as soon as we receive your message.

Any other question, please contact us at info@istardentalsupply.com

Cancellation:

If you wish to cancel your order before shipment, please contact us within 12 hours of placing your order using the contact form or email info@istardentalsupply.com. If you notify us after 12 hours of placing your order, we may not be able to cancel it.

After we receive your message, we will promptly cancel your order and refund the money to your account within 48 hours.

 

Return & Exchange:

1、Return and exchange terms

To qualify for a return, your merchandise must be unused and in the same condition as when you received it.

(1) Your merchandise must be in its original packaging.

(2) You must notify us of your intention to return the merchandise within 15 days of receiving it.

(3) Returned items must be received within 20 days after the return request form is issued.

Please note: For health and hygiene reasons, we do not accept returns of opened dental handpieces, dental intraoral cameras, dental air polishers, and similar items unless defective.

 

2、Defective Items Purchased Online

If you receive an item you believe to be defective, or if there is an issue with a purchase you made, please contact us via the contact form or email. A member of the Istar team will assist in resolving the issue or provide you with the necessary return forms.

 

3、Return and Exchange Information

If you wish to return or exchange items, please provide the following information to us.

(1) Order number

(2) Proof of payment

(3) Product images

 

4、Return/Exchange Process

Contact us via the contact form or email info@istardentalsupply.com, and we'll respond within 12 hours.

 

Return Shipping Fee

Unless otherwise specified, you are responsible for the cost of returning items to us. We recommend all returns be sent back to us via a tracked service, and if the value of the goods exceeds $50, please use an insured service. We are not liable for any returns lost in transit.

Please Note: All returns for both unwanted or faulty items must be logged via our ticketing system. Unauthorised returns unfortunately will not be processed.

 

Refunds

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item. If your return is approved, we will initiate a refund to your credit card (or original method of payment).

You will receive the credit within 3-5 workings days depending on your card issuer's policies.

 

After-Sales Contact Information

Tel: +1 430 422 6876

Email: info@istardentalsupply.com

Note: Please contact us before returning any items, otherwise any returns will be refused.

You may also like