Wireless Cordless Dental Endo Motor With Built-in Apex Locator, 360° Adjustable Handpiece, Root Canal Preparation Machine

Istar Dental SupplySKU: GLJG-ALEM-1

Quantity: 1 Pcs($472/ea)
Voltage: 220V 50Hz
Plug: USA Plug
Price:
Sale price$472.00
Chat on WhatsApp
Free Shipping
United States: in 5-15 days. 0ther Countries: in 15-20 days.
Return & Refund
Returnable within 30 days for return or refund.
Free Registration
Sign up and get 5% off your first order.
Warranty Time
The warranty period for our dental equipment is 6 months

Description

Built-In Apex Locator: With the integrated apex locator, the motor will response according to setting when the file reaches the apical point. It can be reverse, slow down, stop and off.

Safer Treatment Process: The equipment integrated apex locator function, the motor will start automatically after the endo file entering root canal when the lip hook is connecting with patient.

Excellent User Experience: Colorful LCD Screen, Clear panel buttons and screen display.

Multiple Settings: The equipment has 10 memory programs. All these parameters can be changed. Parameters can be set according to the user manual.

Contra-Angle Rotary 360 Freely: The contra angle can rotate in 360°without taking off, making it easy to watch the LCD screen.

High-Efficiency Treatment: The 1900mAh battery supports longer treatment times, and the contactless charging design allows for more convenient operation.

Parameter:

Dimensions

27.3*29*201mm

Weight

156g

Contra angle

Suitable for 2.35mm nickel-titanium root canal files

Battery

(lithium battery) 3.7V 1900mAh

Input Adapter

single phase 100-240V 50/60Hz 0.4A Max

Output Adapter

5V/1A

Rated power

5VA

Torque range

0.5N·cm-4N·cm

Applied part type

120-1000rpm

Output voltage

B

Working environment

Ambient temperature

5°C~40°C

Relative humidity

30~75%

Transportation and storage conditions

Ambient temperature

-20°C~ 55

Relative humidity

10%~93%

Packing List:

Item

PCS

Contra angle

1

Handpiece

1

Charging base

1

Adapter

1

Spray nozzle

1

File clip

2

Lip hook

2

Measuring wire

1

Tester

1

Insulating layer

1

 

Installation:

1. Installing the contra angle: Make sure 3 pins on contra angle align the slots of handpiece, plug them together until there is an audible click. A click sound indicates that the installation is in place. After connecting the contra angle and handpiece, pull it gently to make sure the connection is good. Make sure the contra angle is inserted properly into the handpiece before use.

2. Installing the file: Turn the file back and forth until it is oriented with interior latch groove and slips into place, lock the file into the contra angle.

Hold down the push button on the contra angle and release the file.

3. Connecting the measuring wire: If you want to activity apex measurement function,connect the handpiece with measuring wire,white slot for lip hook, dark slot for file clip.

4. Connecting the charge base: Plug the USB of adapter into the charging base, then plug the other end into a power outlet, the power LED on charging base will light up.

Trouble Shooting:

Check the following points when something wrong with the motor. if the problems still can't be solved, please contact your distributor.

Problem

Cause

Solution

Unable to turn power on

Low power

Charge the battery

Press time is too short

Press the main switch over 0.5 seconds

Charging indicator doesn't flash on handpiece screen

Wrong direction on charging base

Check the connection

The charge pin of charging base is unable to rebound

Remove debris of the charge pin

Contactors are dirty

Cleaning the surface of contactors

The charging base is broken

Using adapter to recharge,and contact your distributor

Handpiece screen doesn't display

The handpiece is broken

Press to main switch to check to sound and if there is a sound of motor rotation. If not, contact your distributor

Motor doesn't rotate

The contra angle is clogged

Unplug the contra angle to check whether the motor rotates, if so, clean or replace the contra angle

Motor is broken or protected by the system

Check the "Error Warning"

Motor can't stop

There's a short circuit inside the motor

Press s button to stop and contact your distributor

Motor spontaneously starts running in reverse

Up to setting torque limit

Check the torque limit is enough or not

REV mode is set

Changing setting if it's not expected

Motor does not reverse

R.L mode is set

Changing setting if it's not expected

Torque reverse setting might be too high

Changing setting if it's not expected

Motor alternates between FWD and REV rotation

REC or ATC mode is set

Change setting if it's not expected

No sound

Beep volume is set to 0

Set beep volume to 1,2 or 3

Continuous alarm

REV or R.L mode is set

Ignore the alarm if it is expected mode

Canal

measurement is unstable

Complex root canal situation

Check situation of root canals

Cannot make a measurement

Incorrect connection of measuring wire, lip hook or file clip

Check the connection

Improper connection between the file and file clip

Replace the file

Check the root canal

Unsuitable situation of root canals

Check the root canal environment

 

Payment & Security

Visa Mastercard American Express PayPal Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

All of our products come with free shipping, so please don't worry about shipping.

We have put a lot of focus on making sure the items get delivered to our customers as quickly as possible.

The total time is the sum of the processing time and the shipping time. Processing time = the time between when you place an order and when we ship it; Shipping time = the time between when your order has been shipped and deliveto you;

All products have a 1 day processing time

For most products, processing time is 1 day and shipping time is 7-20 days.
In the United States it usually takes 7-15 business days to receive your order; in other countries it can take up to 15-20 days to receive your order.

For large dental equipment, such as dental chairs, the processing time is 1-3 days and shipping time is usually 30-40 days.

All of this information is described inside the product details, if you would like to confirm a more precise time, please contact us and we will calculate it for you as soon as we receive your message.

Any other question, please contact us at info@istardentalsupply.com

Cancellation:

If you wish to cancel your order before shipment, please contact us within 12 hours of placing your order using the contact form or email info@istardentalsupply.com. If you notify us after 12 hours of placing your order, we may not be able to cancel it.

After we receive your message, we will promptly cancel your order and refund the money to your account within 48 hours.

 

Return & Exchange:

1、Return and exchange terms

To qualify for a return, your merchandise must be unused and in the same condition as when you received it.

(1) Your merchandise must be in its original packaging.

(2) You must notify us of your intention to return the merchandise within 15 days of receiving it.

(3) Returned items must be received within 20 days after the return request form is issued.

Please note: For health and hygiene reasons, we do not accept returns of opened dental handpieces, dental intraoral cameras, dental air polishers, and similar items unless defective.

 

2、Defective Items Purchased Online

If you receive an item you believe to be defective, or if there is an issue with a purchase you made, please contact us via the contact form or email. A member of the Istar team will assist in resolving the issue or provide you with the necessary return forms.

 

3、Return and Exchange Information

If you wish to return or exchange items, please provide the following information to us.

(1) Order number

(2) Proof of payment

(3) Product images

 

4、Return/Exchange Process

Contact us via the contact form or email info@istardentalsupply.com, and we'll respond within 12 hours.

 

Return Shipping Fee

Unless otherwise specified, you are responsible for the cost of returning items to us. We recommend all returns be sent back to us via a tracked service, and if the value of the goods exceeds $50, please use an insured service. We are not liable for any returns lost in transit.

Please Note: All returns for both unwanted or faulty items must be logged via our ticketing system. Unauthorised returns unfortunately will not be processed.

 

Refunds

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item. If your return is approved, we will initiate a refund to your credit card (or original method of payment).

You will receive the credit within 3-5 workings days depending on your card issuer's policies.

 

After-Sales Contact Information

Tel: +1 430 422 6876

Email: info@istardentalsupply.com

Note: Please contact us before returning any items, otherwise any returns will be refused.

You may also like