Features:
Human Body Safe Operation Design
Dental air purifier can be operated in the presence of a person without any damage to the human body, ensuring that the user can enjoy a clean air environment at any time.
High-Quality Galvanised Steel Shell
The dental air purifier shell is made of high-quality galvanised steel with good anti-aging and anti-spontaneous combustion properties, and adopts an upper inlet and lower outlet structure to achieve efficient air circulation and improve indoor air quality.
Two-Stage Plasma Field And Enhanced Disinfection Function
The hospital grade air purifier new two-stage plasma field inside the unit is effective in sterilisation and dust accumulation. Enhanced disinfection function can urgently deal with indoor infections and protect the environment.
Intelligent Reminder And Display Function
This air filtration for dental offices adopts modular design, which is convenient for daily maintenance, and has the function of automatic accumulation of working time and cleaning reminder to ensure that the equipment always operates efficiently. LCD Chinese display and far infrared remote control design, one key lock function to prevent misoperation, increase the ease of use.
Multi-Mode And Remote Control Design
The device supports three-block airflow adjustment, manual and reservation mode, and the reservation mode can be set to switch on and off in 9 time slots to meet the needs of users. Magnetic remote control can be attached to the body, easy to access and prevent loss.
Multi-Layer Filtration System
Hospital grade air purifier is equipped with a primary filter, which effectively removes PM2.5 and fine bacteria; and a high-quality activated carbon molecular filter, which is specially designed to remove organic gases and odours, keeping the air fresh and odourless.
Negative Oxygen Ion Function And Intelligent Alarm
Additional negative oxygen ion release function makes the air fresher. In addition, equipped with plasma sterilisation and purification module, fan, temperature and humidity sensors and other fault alarm functions to ensure the stability and safety of the equipment.
Parameter:
Dimensions
|
(L×W×H): 720×320×160 (mm³) |
Weight |
18 kg |
Disinfection method |
plasma |
Maximum applicable volume |
60 m³ |
Rated circulation air volume |
600 m³/h |
Noise |
≤55dB(A) |
Negative ion concentration |
≥6×106/cm³ |
Plasma field strength |
8 kV±0.3 kV |
Particle (0.5μm) removal rate |
>99.99% |
The killing rate of bacteria in the aerosol chamber is |
>99.99% |
The average extinction rate of natural bacteria (disinfection time 60min) is |
>98.00% |
Equipment Installation:
This unit is a wall-mounted model, and the placement should be on a wall that is sturdy, not susceptible to vibration, and strong enough to withstand the weight of the unit. Choose a place that is not close to heat and steam sources and will not create obstacles to the inlet and outlet of the unit. Choose a place where the air can be sent to all corners as far as possible. Choose a place close to the power socket and leave enough space near the machine.
Precautions:
① Please read the instruction manual carefully before use.
② Use a standard three-core, single-phase power outlet with a 220V supply voltage and good grounding.
③ Do not place other manufacturers' parts in the machine.
④ Unplug the power supply before cleaning and maintenance.
⑤ Do not expose the electrical system to moisture during cleaning as this may cause accidents or malfunctions.
⑥ During the use of the machine will occasionally emit ‘crackling’ fire sound, is a normal phenomenon, if continuously issued according to the 8th troubleshooting treatment.
⑦ Non-professionals are strictly prohibited to disassemble the machine.
⑧ In the flat surface when moving the middle part of the equipment should be gently push the hand to move slowly.
⑨ In up and down the lift should pay attention to the protection of the casters, if necessary, the equipment should be slightly raised on one side.
When moving up and down stairs or on rough and uneven ground, the equipment should be lifted up and moved.
Trouble Removal:
Problem
|
A Possible Solution
|
There is no air out of the outlet after the new machine is turned on.
|
Please check whether the power supply is connected and whether there is debris blocking the inlet and outlet.
|
The product is started but the button cannot be operated.
|
Check whether the product is in the child lock state, if yes, please press and hold the remote control "lock" button to unlock the button.
|
The remote control cannot be used.
|
Check whether the power insulation strip of the remote control is removed.
|
The product sounds too loud.
|
Please check whether the inlet and outlet are blocked by foreign objects and whether the cover screw is loose.
|