VRN® Orthodontic Curing Lights, 10W High Power Blue Led Curing Light Dental

Istar Dental SupplySKU: WR-CL-01

Voltage: 220V 50Hz
Plug: USA Plug
Price:
Sale price$304.00
Chat on WhatsApp
Free Shipping
United States: in 5-15 days. 0ther Countries: in 15-20 days.
Return & Refund
Returnable within 30 days for return or refund.
Free Registration
Sign up and get 5% off your first order.
Warranty Time
The warranty period for our dental equipment is 6 months

Description

Characteristic

1. Constant Light Power And Highly Efficient Parallel Light Output

The constant light power design of the unit ensures that the intensity of the light output will not be affected even when the battery power drops, ensuring high quality curing results at all times. At the same time, the parallel light source design focuses the energy on the target area, providing a more effective curing experience for all types of resin materials.

2. Compliant With Wireless Charging Standards For Long Life

Using wireless charging technology that complies with QI WPC V1.1 standard, the electro-optical conversion efficiency is so high that it can be used more than 500 times (based on 10-second timing) in full-power mode after a full charge, ensuring uninterrupted operation for a long period of time. In addition, the charging base has an optometry function that detects whether the radiation output meets the curing requirements, providing a guarantee of operational safety.

3. Ergonomic Design And Durable Aluminium Alloy Body

The body is made of aluminium alloy, which has good anti-drop and anti-drop performance, and the ergonomic design of the handle improves the sense of grip and brings better operating stability and comfort. The light source head supports 360°rotation, adapting to the needs of multi-angle curing, facilitating flexible adjustment and enhancing the convenience of use.

4. Multi-Functional Integrated Light Source Head Design

Equipped with a detachable light source head, it can be flexibly adapted to 400nm-420nm band light source, which is suitable for caries detection. In addition, a special whitening wand provides blue light to enhance the whitening effect. The device also supports the replacement of special spot-curing lenses, which facilitates the ideal curing effect when bonding porcelain veneers, crowns and root canal fibre stumps.

5. Replaceable Lithium Battery And Smart Switch-Off Function

The curing light is equipped with a replaceable lithium battery with an automatic switch-off function, which effectively extends the battery life and ensures energy saving when the unit is on standby, meeting the needs of long-time and multiple operations.

 

Basic Parameter

Standard Voltage

3.7V

Capacity

2200mAh

Battery Model

ICR 18650

Power Adapterinput

AC 100-240v, 50/60Hz

Fuse

T1AL 250V

Input Power

22VA

Output

DC 5V/1A

Features of Led light

10Watt high power blue led light

Class

Class I

Wave Length

385nm-515nm

Checking

Led light works under proper use

Radiation

≥850 mW/cm2

Optical effective area

75mm2

 

Operational Approach:

Press and hold the ‘Δ’ button (about 1 second, release after the buzzer sounds), you can choose any one of the following three modes to enter the working state:

1.Full power mode: the ‘Π’ symbol is shown in the middle of the right side of the display, the blue light is irradiated at full power (clinically recommended mode).

2. Progressive mode: The ‘Л’ symbol is shown in the middle of the right side of the display, and the blue light power is gradually increased from weak to reach the maximum power in 5 seconds.

3. Pulse mode: The ‘пп’ symbol is shown in the middle of the right side of the display, and the blue light works in pulse mode.

Long press the light curing machine ‘Δ’ button (about 2 seconds, the buzzer sounded two times after the release), you can choose the following three power density output:

1. Ultra-high power density: the bottom of the right side of the display shows ‘P1’, the blue light to the maximum power density of irradiation (2300mW/cm2~2500mW/cm2).

2. High power density: the bottom of the right side of the display shows ‘P2’, blue light with high power density irradiation (1600mW/cm2 ~ 1800mW/cm2).

3. Standard power density: the bottom right side of the display shows ‘P3’, blue light irradiation at standard power density (1000mW/cm2~1200mW/cm2).

Lightly press the ‘A’ button of the light curing machine to set the light curing time.

1.P3 mode can select 1, 2, 3, 4, 5, 10, 15, 20, 25, 30, 35, 40 seconds.

2.P2 mode selects 1, 2, 3, 4, 5, 10, 15, 20 seconds.

3.P1 mode can select 1, 2, 3 seconds of timing time.

 

Safety & Precautions:

1.The product must be used within the scope mentioned in the instruction manual and cannot be used for other purposes.

2. Please charge the machine for at least 4 hours for the first time.

3. The disposable isolation sleeve is strictly prohibited from re-use to prevent cross infection.

4. The head of the host can be rotated 360 degrees and can be disassembled and replaced.

5. The light curing machine should be used by trained personnel.

6. The light curing machine should be placed in a place where children can not touch.

7. When used clinically, the light source should be directly irradiated on the cured resin material, to prevent improper irradiation position, which may affect the curing.

Prevent improper irradiation position, affecting the curing effect.

8. Must use the manufacturer's original shades or goggles, is strictly prohibited to irradiate the eyes, otherwise it will cause damage to the eyes.

9. Please use the original charger, other chargers may cause damage to the lithium battery and control circuit.

10. Strictly prohibit the use of metal placed on the surface of the charging seat, so as not to become the internal electrical circuit burned: not charging, please unplug the power supply.

11. Please charge the battery in a cool, ventilated room.

12. It should be operated strictly according to the rated working time specified in the instruction manual to avoid damage to the teeth caused by too high temperature rise. After 5 consecutive operations should be switched off until the LED cools down and then switched on again.

13. It is strictly prohibited to squeeze, vibrate or shake the battery, short-circuit the battery, put the battery with metal objects, and disassemble the battery without permission.

14. If the machine is not used for a long time, the lithium battery and the host must be separated, removed and stored separately.

15. It is recommended not to use high-frequency and high-pressure equipment in the surrounding 5M range, so as not to affect the performance of the equipment or abnormal work.

 

Trouble Removal:

Failure State

Probable Cause

Handling Method

No indication, no action

1. the battery in the light curing machine has no electricity

2. The battery is damaged

3. Host battery protection

1. Connect to the power supply to charge/replace the battery

2. Replace the battery

3. Connect to the charger to charge and activate

The display is abnormal

Host failure

Send to maintenance department for repair

· Display character blink

 

The light source is not installed or is not properly installed

Reinstall the light source and send it to the maintenance department if the fault is not solved

Underlight

The light source is polluted by the light port

Please clean up the contamination

No charge after connecting to the power adapter

 

 

1. The power supply is not plugged in

2. The power adapter is damaged or does not match the specifications

3. Charging seat broken

1. Pull out and plug it in again

2. Replace the charger

3. Send to maintenance department for repair

Battery life becomes shorter after charging

 

 

Smaller battery capacity

 

 

Replace battery

Payment & Security

Visa Mastercard American Express PayPal Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

All of our products come with free shipping, so please don't worry about shipping.

We have put a lot of focus on making sure the items get delivered to our customers as quickly as possible.

The total time is the sum of the processing time and the shipping time. Processing time = the time between when you place an order and when we ship it; Shipping time = the time between when your order has been shipped and deliveto you;

All products have a 1 day processing time

For most products, processing time is 1 day and shipping time is 7-20 days.
In the United States it usually takes 7-15 business days to receive your order; in other countries it can take up to 15-20 days to receive your order.

For large dental equipment, such as dental chairs, the processing time is 1-3 days and shipping time is usually 30-40 days.

All of this information is described inside the product details, if you would like to confirm a more precise time, please contact us and we will calculate it for you as soon as we receive your message.

Any other question, please contact us at info@istardentalsupply.com

Cancellation:

If you wish to cancel your order before shipment, please contact us within 12 hours of placing your order using the contact form or email info@istardentalsupply.com. If you notify us after 12 hours of placing your order, we may not be able to cancel it.

After we receive your message, we will promptly cancel your order and refund the money to your account within 48 hours.

 

Return & Exchange:

1、Return and exchange terms

To qualify for a return, your merchandise must be unused and in the same condition as when you received it.

(1) Your merchandise must be in its original packaging.

(2) You must notify us of your intention to return the merchandise within 15 days of receiving it.

(3) Returned items must be received within 20 days after the return request form is issued.

Please note: For health and hygiene reasons, we do not accept returns of opened dental handpieces, dental intraoral cameras, dental air polishers, and similar items unless defective.

 

2、Defective Items Purchased Online

If you receive an item you believe to be defective, or if there is an issue with a purchase you made, please contact us via the contact form or email. A member of the Istar team will assist in resolving the issue or provide you with the necessary return forms.

 

3、Return and Exchange Information

If you wish to return or exchange items, please provide the following information to us.

(1) Order number

(2) Proof of payment

(3) Product images

 

4、Return/Exchange Process

Contact us via the contact form or email info@istardentalsupply.com, and we'll respond within 12 hours.

 

Return Shipping Fee

Unless otherwise specified, you are responsible for the cost of returning items to us. We recommend all returns be sent back to us via a tracked service, and if the value of the goods exceeds $50, please use an insured service. We are not liable for any returns lost in transit.

Please Note: All returns for both unwanted or faulty items must be logged via our ticketing system. Unauthorised returns unfortunately will not be processed.

 

Refunds

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item. If your return is approved, we will initiate a refund to your credit card (or original method of payment).

You will receive the credit within 3-5 workings days depending on your card issuer's policies.

 

After-Sales Contact Information

Tel: +1 430 422 6876

Email: info@istardentalsupply.com

Note: Please contact us before returning any items, otherwise any returns will be refused.

You may also like