VRN® LED Curing Light, Dental Curing Light, Orthodontic Curing Light

Istar Dental SupplySKU: RF-CL-1

Quantity: 1 Pcs($166/ea)
Voltage: 220V 50Hz
Plug: USA Plug
Price:
Sale price$166.00
Chat on WhatsApp
Free Shipping
United States: in 5-15 days. 0ther Countries: in 15-20 days.
Return & Refund
Returnable within 30 days for return or refund.
Free Registration
Sign up and get 5% off your first order.
Warranty Time
The warranty period for our dental equipment is 6 months

Description

Features:

Constant Light Power Output And Wide Spectrum Light Source

The curing lamp adopts constant light power design to ensure that the curing effect will not be affected even when the battery power gradually decreases, and can always maintain a stable and powerful light output. With the parallel light source technology, the energy output is more concentrated and precise, which is suitable for curing most of the commercially available resin materials with high efficiency. The broad-spectrum light curing function covers a wavelength range from 385nm to 515nm, ensuring that all types of photosensitive resin materials can be cured uniformly, regardless of material type.

Three Light Intensity Levels And OLED Display

The device supports three light intensity levels, allowing the user to select the appropriate intensity setting according to the actual curing needs to adapt to different treatment conditions and material thicknesses, and the OLED screen clearly displays the current light intensity level at a glance, allowing the user to grasp the real-time status of the device and achieve more precise operational control to further improve treatment results.

Light Measurement Function To Verify The Performance Of The Device

A light measurement device is configured on the base of the device, which can verify whether the light curing machine has reached the appropriate radiation value, thus guaranteeing the curing effect. Before each use, it is easy to quickly check whether the equipment is in the best condition to ensure that the output energy meets the curing requirements, which helps to ensure the safety and accuracy of the treatment process.

Multi-Functional Integrated Design And Flexible Rotating Head

This curing lamp combines the functions of caries detection and resin curing in one unit, allowing healthcare professionals to switch between diagnosis and treatment without changing the lamp head, which significantly improves the ease of operation. The lamp head supports 360° rotation and can be adjusted flexibly according to the needs, which makes it easy to access all areas of the mouth, especially when operating on posterior teeth and complex oral positions, and is suitable for quickly switching treatment angles and improving patient comfort.

Versatile Working Modes

To meet different curing needs, the device offers three operating modes: full power mode, progressive mode and pulse mode. The full power mode is suitable for strong curing scenarios, while the gradual mode is suitable for more gentle curing needs, effectively preventing heat build-up and reducing irritation to the material and teeth. Pulse mode is particularly good in high-intensity, short-term curing scenarios, offering customisable light patterns to enhance operational efficiency and ensure flexibility in responding to complex treatment needs.

 

Basic Parameter

Total Body Size

Diameter22.5mm   Length217mm

Size Of Machine Head

Diameter14.98mm   Length68.6mm

Package Size(inside empty size)

236mm×176mm×96mm

Net Weight

117g

Total Product Packaging Weight

800g

Wavelength Coverage

385nm-515nm

 

Operating Instructions:

Press button "M/T" for 1 second and release the button when the buzzer warns for once. Following three modes are available.

1. Full Power Mode: The screen shows "П", The output light intensity is full-power.(recommended mode for clinical).

2. Progressive Mode: The screen shows "Л" , The output light intensity enhances gradually, power output is to maximum after 5 seconds.

3. Pulsed Mode: The screen shows" n n ", The blue light works in pulse manner.

Press button "M/T" for 2 second and release the button when the buzzer warns for twice. Following four modes based on output of power density are available.

1. Ultra High Power Density: The screen shows "P1",The power density is about 2200 m W/cm'~2600m W/cm2

2. High Power Density: The screen shows "P2", The power density is about 1500 m W/cm2~1900 m W/cm2.

3. Standard Power Density: The screen shows "P3", The power density is about 900mW/cm2~1300mW/cm2

4. Caries Detection Power Density: The screen shows "P4" and "CHECK"and the purple light is output independently. The purple light works under proper use can be regarded as normal.

Tap button "M/T" to select working time interval.

1. In"P3"mode, the time interval can be chose from 1,2,3,4,5,10,15,20.

25,30,35,40 second.

2. In"P2"mode, the time interval can be chose from 1,2,3,4,5,10,15,20second.

3. In"P1"mode, the time interval can be chose from 1,2,3, second.

4. In"P4"mode, the time interval can not be chose.

 

Precautions:

1. Using the product according to the instruction manual,other tasks are out of support.

2. Please charge the battery at least 3 hours before first time usage.6.3 In order to prevent cross-infection, it is forbidden to reuse the disposable sleeve.

3. The top of the main unit can be turned by 360 degree and it is demountable and replaceable.

4. DV-50 LED light curing device only Used by professionally trained people.

5. Please put it away from the touch of kids.

6. During operation, the light should be aimed straightly at the dental resin composite to ensure the effect of solidification.

7. Avoid aiming the light at eyes, please use brake sack or protective goggles supplied by our company to protect your eyes.

8. Please use the power adapter which is designed and supplied by our company. It may cause potential dangers to lithium and control circuit by using the power adapter designed or supplied by other manufacturers.

9. It is forbidden to put metal on the charger because it may burn the internal circuit. Unplug the plug of charger when not charging.

10. Please charge the battery in cool and ventilated room.

11. The product should not be used more than rated working time set in the instruction manual to avoid damaging teeth for the high temperature.Shut down and cool the product when it is used for 5 times continuously.

12. It is forbidden to extrude, shake or rock the battery. It is forbidden to self-taking apart the battery, in order not to result in short-circuit or leakage and it is forbidden to put the battery with metal.

13. Long time do not use the product, please take the lithium battery apart form the main unit. It is recommended that the product should be installed at the medical site where there are no high frequency high voltage equipment within 5 meters to ensure the product work properly.

 

Trouble Shooting:

Faulty

Possible Cause

Solutions

No indication, no response four

1. Battery is out of power.

2. Faulty of battery

3. The main unit battery protection system works.

1. Charge the product/change battery

2. Change battery

3. Place the main unit on the charge for activation.

Ershown on the screen

Faulty of main unit.

Send to after-sale service for repair.

Light intensity is weak.

There is resin on the top of the main unit.

Clear the resin.

The equipment is not charging when the adapter is connected.

1. The adapter is not connected well.

2. Faulty from adapter or incompatible.

3. The charger is out of order.

1. Reconnect

2. Change the adapter

3. Send to after-sale service for repair.

Usage time shortened on a single full charge.

Smaller battery capacity.

Change battery

Note: If such solutions are completed, the product still cannot work normally,please contact with the distributor.

Payment & Security

Visa Mastercard American Express PayPal Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

All of our products come with free shipping, so please don't worry about shipping.

We have put a lot of focus on making sure the items get delivered to our customers as quickly as possible.

The total time is the sum of the processing time and the shipping time. Processing time = the time between when you place an order and when we ship it; Shipping time = the time between when your order has been shipped and deliveto you;

All products have a 1 day processing time

For most products, processing time is 1 day and shipping time is 7-20 days.
In the United States it usually takes 7-15 business days to receive your order; in other countries it can take up to 15-20 days to receive your order.

For large dental equipment, such as dental chairs, the processing time is 1-3 days and shipping time is usually 30-40 days.

All of this information is described inside the product details, if you would like to confirm a more precise time, please contact us and we will calculate it for you as soon as we receive your message.

Any other question, please contact us at info@istardentalsupply.com

Cancellation:

If you wish to cancel your order before shipment, please contact us within 12 hours of placing your order using the contact form or email info@istardentalsupply.com. If you notify us after 12 hours of placing your order, we may not be able to cancel it.

After we receive your message, we will promptly cancel your order and refund the money to your account within 48 hours.

 

Return & Exchange:

1、Return and exchange terms

To qualify for a return, your merchandise must be unused and in the same condition as when you received it.

(1) Your merchandise must be in its original packaging.

(2) You must notify us of your intention to return the merchandise within 15 days of receiving it.

(3) Returned items must be received within 20 days after the return request form is issued.

Please note: For health and hygiene reasons, we do not accept returns of opened dental handpieces, dental intraoral cameras, dental air polishers, and similar items unless defective.

 

2、Defective Items Purchased Online

If you receive an item you believe to be defective, or if there is an issue with a purchase you made, please contact us via the contact form or email. A member of the Istar team will assist in resolving the issue or provide you with the necessary return forms.

 

3、Return and Exchange Information

If you wish to return or exchange items, please provide the following information to us.

(1) Order number

(2) Proof of payment

(3) Product images

 

4、Return/Exchange Process

Contact us via the contact form or email info@istardentalsupply.com, and we'll respond within 12 hours.

 

Return Shipping Fee

Unless otherwise specified, you are responsible for the cost of returning items to us. We recommend all returns be sent back to us via a tracked service, and if the value of the goods exceeds $50, please use an insured service. We are not liable for any returns lost in transit.

Please Note: All returns for both unwanted or faulty items must be logged via our ticketing system. Unauthorised returns unfortunately will not be processed.

 

Refunds

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item. If your return is approved, we will initiate a refund to your credit card (or original method of payment).

You will receive the credit within 3-5 workings days depending on your card issuer's policies.

 

After-Sales Contact Information

Tel: +1 430 422 6876

Email: info@istardentalsupply.com

Note: Please contact us before returning any items, otherwise any returns will be refused.

You may also like