- This high speed air turbine handpiece screws straight onto a 2-hole or 4-hole hose. Both versions cost the same, and no coupler is needed.
- Rated 320,000–350,000 rpm free-running on 0.22–0.25 MPa (32–36 psi) of drive air, with noise at or under 60 dB.
- Push-button chuck for FG burs, ceramic bearings, single-port water spray.
- The turbine cartridge lifts out of the head, so a worn one can be swapped.
- Autoclavable at 135 °C (275 °F). The price per handpiece drops at 5 and again at 10 pieces.
This high speed air turbine handpiece is the plain, screw-on model in our range: no light, no quick coupling. Its back end threads onto your unit's high-speed hose, drive air from the unit spins the turbine, and a push-button chuck holds standard FG burs. Some catalogs call the same kind of instrument an airotor handpiece.
It's also a handpiece worth owning several of. Every turbine wears out sooner or later, and every handpiece goes through the sterilizer after each patient, so a chair rarely runs on just one.
Fitting it to your unit: 2 hole or 4 hole
The back of this high speed air turbine handpiece is a threaded nut with the air and water holes inside it. It screws onto the end of the hose directly. Nothing goes in between.
Look at the end of your high-speed hose and count the holes. Two holes: order the 2-hole version. Four holes: order the 4-hole version. The head, turbine and specs are the same on both, and only the connector at the back changes, which is why the price doesn't.
If your current handpieces click onto a coupling instead of screwing on, this one won't attach to that coupling. Our high speed handpiece with quick coupling ships with a coupling of its own.
Ordered 4-hole and found a 2-hole hose? If it's within 12 hours of ordering, message us and we'll cancel; the refund lands within 48 hours. Still unsure? Photograph the end of the hose and send it to us on WhatsApp, and we'll match the version for you.
High speed air turbine handpiece specs
Spec |
Value |
Type |
Air-driven high-speed handpiece, screw-on back |
Connection |
2-hole or 4-hole, pick one above |
Speed |
320,000–350,000 rpm, free-running |
Working air pressure |
0.22–0.25 MPa (32–36 psi) |
Noise |
≤60 dB |
Burs |
FG (friction grip), shank Φ1.595–1.600 mm |
Chuck |
Push button |
Bearings |
Ceramic, double ball bearings |
Turbine cartridge |
Replaceable; the head cap unscrews |
Water spray |
Single port |
Light |
None |
Body |
Metal, diamond-pattern anti-slip grip |
Sterilization |
Autoclavable at 135 °C (275 °F) |
Warranty |
6 months |
Free-running means measured with nothing touching the bur. Expect the speed to drop once you're cutting. The FG shank is one of the shank types in ISO 1797, the international standard for dental instrument shanks, so you can use standard FG burs.
When the turbine wears out
Everything that spins lives in one cartridge inside the head: the rotor, the small blades the drive air pushes against, a bearing at each end and the chuck that grips the bur. That cartridge is the part that wears. Watch for these signs:
- It sounds higher-pitched, rougher or louder than when it was new.
- You can feel vibration through the handle.
- It won't come up to its usual speed at the usual pressure, or it stalls on light cuts.
- The bur wobbles or slips in the chuck.
Take the last one seriously. Run the handpiece outside the mouth with a new bur, and if the wobble is still there, pull it from service. A bur spinning off-center in worn bearings is a bur that can snap.
Once it's worn, you can swap the cartridge or retire the handpiece. The head cap unscrews and the cartridge lifts out (it's shown in the photos above). Cartridges aren't interchangeable between handpiece designs, so ask us on WhatsApp about a replacement for this model before ordering one anywhere else. And at this price, set any repair quote against the cost of a new handpiece before you send one out for service.
Habits that wear a turbine out faster:
-
Pressing the push button while it's still spinning. Wait until it stops. Pressing early rubs the button against the turning spindle and heats the chuck.
-
Sterilizing without lubricating first, when the instruction manual calls for oil before each cycle. Follow the manual's timing and amount.
-
Putting it away damp. Water left in the head after the cycle is how bearings rust.
How many high speed air turbine handpieces per operatory?
The American Dental Association puts handpieces among semicritical items and, summing up CDC guidance, says any handpiece that comes off the unit's air and water lines is cleaned and heat-sterilized between patients. A disinfectant wipe or a soak doesn't count.
So between patients, each handpiece is out of action while it's cleaned, lubricated, run through the sterilizer, dried and left to cool to room temperature. The chair needs another one the whole time. Plan on three per operatory: one in use, one in the sterilizer, one sterile and ready. If your sterilizer cycle plus drying takes longer than a typical appointment, make it four.
That's what the quantity options are for. Five handpieces cover one operatory with two spares on the shelf for when a turbine wears. Ten cover three operatories at three each, plus one spare.
Will it go through your sterilizer?
135 °C (275 °F) is the most this high speed air turbine handpiece is rated for. It's a limit, not a cycle. The cycle itself comes from your sterilizer's instructions and the handpiece manual.
The sterilizer type matters as well, because a handpiece is hollow, with air and water channels running its full length. EN 13060, the European standard for the small steam sterilizers dental offices use, sorts cycles into three types:
-
Type B is validated for hollow and wrapped loads, so a handpiece fits.
-
Type S works only if the sterilizer's maker lists handpieces among the loads that cycle covers.
-
Type N is for unwrapped solid instruments and isn't meant for handpieces.
Whatever the type, let the drying phase run to the end before you take the handpiece out.
What's in the box
Item |
Qty |
High speed handpiece (2-hole or 4-hole, as ordered) |
1 |
Mini wrench |
1 |
Instruction manual |
1 |
Burs and handpiece lubricant aren't included.
Need a light or a smaller head?
This model has neither. For light at the bur, the High Speed Handpiece LED has a built-in LED and a 4-hole water spray. For pediatric patients and tight access, our high speed handpiece for children has an 8.9 mm head. Every model is in our dental handpieces collection.
Shipping, warranty and returns
Shipping. No shipping charge. Orders are processed within a day and flown out, since handpieces travel by air; most US deliveries arrive in 7–15 business days, and elsewhere it's 15–20 days. See our Shipping Policy.
Warranty. 6 months. For a handpiece that arrives faulty or fails during that time, send info@istardentalsupply.com your order number, proof of payment and a few photos of the problem. We answer within 12 hours.
Returns. You have 15 days from delivery to ask for one. We take back unused handpieces in their original packaging; because this is an instrument that goes into patients' mouths, a non-defective one comes back only with a valid reason. Open a return request with us before you ship anything, and plan on paying the return postage unless we've agreed otherwise. Full terms: Return & Refund Policy.
FAQ
Why does it keep spinning after I take my foot off the pedal?
That's normal. The rotor keeps turning on its own momentum for a second or two after the drive air stops. As it slows, it can draw a little fluid back into the head, so treat the inside as contaminated after every patient, even when the outside looks clean.
Can I order more than 10, or buy as a dealer?
Yes. Send the quantity and your 2-hole/4-hole split to us on WhatsApp. For a large order you can pay by bank transfer: half as a deposit, the rest after we've confirmed shipment with you.
Choose 2-hole or 4-hole and a quantity above, then add your high speed air turbine handpiece to the cart.