Visualized Operation: ISDENT apex locator equipped with a color 4.8-inch LCD display screen, the image is clear, and multiple colors cleary indicate the trajectory of the file in the root canal, Enhance doctor's experience.
Convenient User Experience: Foldable, the screen angle can be adjusted according to different environments and workspaces, easy adjustment of viewing angle. Adapt to the needs of doctors.
High Precision Positioning: Based on multi frequency independent network measurement technology, automatic calibration ensures measurement accuracy, give you a quick and efficient measurement process.
Therapeutic Safety Performance: Sound prompt function, When the file is close to the root tip, there will be a beep prompt. Reduce treatment risks. Smooth treatment process. File clips and lip hooks can be disinfected under high-temperature and high-pressure to avoid cross infection.
Long-Lasting Battery Life: The battery is rechargeable and does not need to be replaced repeatedly. The battery is 800 mAh, more cost-effective and environmentally friendly, improving user experience.
Parameter
|
Weight
|
380g only
|
Packaging volume
|
L159xW159xH63mm
|
Power
|
AC 110-220V,50-60Hz
|
Output
|
Voltage DC 5V
|
Battery
|
3.7V/ 800 mAh
|
Power adapter
|
~100V-240V 1A Max 50Hz/60HZ
|
Power consumption
|
≤0.5W
|
Display
|
4.8 inch LCD screen
|
Environmental temperature range
|
+5°C~+40°C
|
Relative humidity range
|
30%~75%
|
Atmospheric pressure
|
70kPa~106kPa
|
Scope of Application
|
Used to assist in determining the working length of root canals forvarious types of teeth during dental clinical root canal treatment.
|
Packing List:
Host*1, Measuring wire*1, file clamp *1, lip hook*2, power adapter*1, User manual *1
Installation:
Preparation for measurement
1. Insert the measuring wire plug into the socket on the right side of the machine.
2. Insert the file clip and lip hook into the sockets of the measuring wire.
3. Line connection test confirmation (test before each use)
a) Press the power switch. Confirm that the LCD screen displays a screen for measuring.
b) Confirm that the measuring wire is properly inserted into the socket of the unit.
c) Confirm that the file clip and lip hook are connected to the socket of the measuring wire.
d) Touch the clip of the file clip on the measuring line with the lip hook. Confirm that
the short-circuit indicator icon on the LCD display is stable, indicating that the line is normal. Otherwise, the file clip or measuring line is damaged and must be replace.
4. Determination of working length
a) When the root canal length indicator reaches position 0.0 of the dial, the root canal file has reached the anatomical apical foramen, and the measured length at this position is subtracted from 0.5 to 1.0mm as the root canal working length.
b ) When the root canal indicator bar indicates the arrival of the red zone OVER. this indicates that the root canal file has exceeded the apical foramen, and a continuous beep will be emitted at the same time.
*Due to the differences of teeth and root canal morphology, the above mentioned root canal length will be different, please make your judgment according to clinical practice.
Note: After measuring the length of the root canal, please be sure to take X-rays for confirmation.
Apex stop settings
a) Due to individual differences, the length of root canal working varies. The measurement of working length always takes into account the respective pathological conditions and is determined according to the clinical experience of the individual. Therefore, the position of the apex stop can be between 0.0 and 1.0 scale and can be set according to the individual use of the apex stop setting key
b)When the display reaches the apex stop, the machine continuously emits a beep to indicate that the set apex stop has been reached.
Battery charging
When the battery residual display flashes, please do not continue to use it When the display flashes, it indicates that the remaining power is low.
1. Insert the AC power adapter plug into the left side socket of the machine, and then insert the AC adapter power plug into the power socket.
2. The yellow charging indicator light is on, indicating that the machine is in the charging state. The indicator light changes from yellow to green,indicating that the charging is over. It takes about 120 minutes for the machine to be fully charged.
3. After charging, please unplug the AC power adapter and power plug.Note: When the AC power adapter is charging on the power supply, the machine cannot be used, and it must be kept away from the machine when charging, The patient's operating area is more than 2 meters.
Trouble Removal:
Troubles
|
Inspection items
|
Fault analysis and treatment
|
Turning on the power does not light up, and the display screen does not display
|
ls the battery low incharge?
|
Charge in a timely manner.
|
Unable to measure root canal length
|
Are the accessories used connected correctly?
|
Confirm that the measuring wire socket is securely inserted, and contact the lip hook with the file clamp to check if the measuring wire is broken.
|
The buzzer does not sound
|
Is the volume set to mute?
|
Change the volume setting for beeps.
|
Unstable display during measurement. The measured length is too long or too short, Poor accuracy and irregular numerical display
|
Does the lip hook maintain good contact with the oral mucosa?
|
Move the lip hook to a position that maintains good contact with the oral mucosa.
|
Is blood or medication spilling and sticking to the crown of the teeth?
|
When blood or medicinal liquid overflows from the root canal and gets stuck on the crown or neck of a tooth, it can cause a short circuit,resulting in abnormal phenomena. Dry the spilled blood and medication and measure it.
|
ls the root canal filled with blood and medication?
|
When the root canal file comes into contact with the liquid level filled with blood and medication in the root canal, the display will immediately jump to "OVER". In this case, pushing the root canal file towards the root tip will naturally restore the display to normal, allowing for accurate measurement of the root canal length.
|
Is there any medication or debris on the tooth surface?
|
Clean the tooth surface thoroughly.
|
Does the root canal file come into contact with the gums?
|
After the root canal file comes into contact with the gum, the LCD display screen will immediately jump to "OVER".
|
ls there still pulp left in the root canal?
|
When there is still a large amount of pulp left in the root canal, it is not possible to accurately measure the length of the root canal operation.
|
Unstable display during measurement; The measured length is too long or too short; Pool accuracy and irregular numerical display
|
Does the root canal file touch the metal restoration?
|
After the root canal file comes into contact with the metal restoration, the measurement of current loss from the gum or periodontal tissue will immediately jump to "Over".
|
ls there caries on the adjacent surface?
|
The measurement of current flowing from adjacent caries teeth to gingiva cannot accurately determine the length of root canal operation.
|
Are there any side branches or broken tooth roots?
|
When the root canal file reaches the opening of the lateral branch or the broken part of the tooth root, the measured current will flow out of the periodontal ligament and the display will immediately jump to "Over".
|
Is it because the top of the pulp chamber has been removed that the crown of the tooth is low? Are there any residual roots left?
|
Use a rubber barrier to prevent electrical current from flowing to the gums.
|
ls there a cyst at the tip of the tooth root?
|
In the case of cysts, the length of the root canal cannot be accurately measured.
|
ls the file clip dirty or damaged?
|
Clean or replace the file clip with disinfectant alcohol.
|
ls the measuring wire damaged or in poor contact?
|
Short circuit both ends of the measuring wire, and the short circuit test icon will display stably, indicating that there are no abnormalities in the connection of the measuring wire.
|
The length measurement indicator bar is only fully displayed near the apical stenosis
|
Is the root canal occluded?
|
After penetrating the narrow part of the root tip, the display will be normal.
|
Is the root canal extremely dry?
|
Wet the root canal with sodium hypochlorite solution or physiological saline solution.
|
Is it a small root canal file used in a large root canal?
|
Choose the appropriate number of root canal files.
|