Dental Sterilization Machine , Fully Automatic Autoclave, Digital Display Touch Screen, 18L/23L

Istar Dental SupplySKU: QD-AC-01-1

Volume: 18L
Price:
Sale price$2,188.00
Chat on WhatsApp
Free Shipping
United States: in 5-15 days. 0ther Countries: in 15-20 days.
Return & Refund
Returnable within 30 days for return or refund.
Free Registration
Sign up and get 5% off your first order.
Warranty Time
The warranty period for our dental equipment is 6 months

Description

Features:

1. Intelligent Monitoring & Diagnostic System

The autoclave dental is equipped with advanced intelligent monitoring and diagnostic system, which detects the operation condition in the whole sterilisation process in real time, and once a fault occurs, the system automatically locates the faulty parts in sections and provides detailed fault information and simple solutions. The system is called a ‘smart technician’, with real-time diagnosis and intervention capabilities, significantly improve the maintenance efficiency, so that maintenance and repair more convenient and quick.

2. Traceability Of Sterilisation Data

Standard with large-capacity memory, automatic recording of sterilisation data, convenient for subsequent enquiry and retrieval. It can also be equipped with an external thermal printer, which can automatically print the sterilisation data and results at the end of each sterilisation procedure, ensuring the full recording and tracking of the sterilisation process, which is in line with the high requirements of medical data management.

3. Efficient Preheating System

Pre-heating standby function maintains the temperature at a certain level, reduces the start-up time of sterilisation, makes the whole procedure efficient and quick, achieves energy-saving effect and optimises the sterilisation efficiency.

4. Large Air-Conditioning Type Heat Dissipation Design

Dental autoclave is equipped with 260x142mm large cooling window, combined with 73 layers of cooling aluminium plates and 18 cooling tubes, the hot water is quickly cooled to near room temperature, efficiently protects the drainage channel and prolongs the service life of the equipment.

5. Quick Drainage System

Imported front fast interface, so that water and drainage operations become simple and fast, automatic direct drainage design effectively prevent the pollution of the internal water system. Users can also choose the automatic water filling system, to achieve automatic water supply from the external water tank, further enhance the convenience.

6. Futuristic Handle Design

The futuristic handle design provides a comfortable grip and unique visual experience, enhancing the aesthetics and practicality of the device.

7. Built-In Open Large-Capacity Water Tank

Autoclave in dental clinic is equipped with a 3.4L open water tank to support the water needs of 5 sterilisation cycles, the tank is easy to clean and the user can intuitively monitor the water quality to ensure easy daily maintenance and keep the system clean.

Parameter:

Applicable voltage

220-240 VAC-50/60Hz, single-phase voltage

Rated voltage

220V, 50Hz

Maximum current

10A

Maximum power

1700W

Maximum altitude

Altitude 3500 meters

Maximum working pressure

2.5 Bar(250 kPa)

Minimum working pressure

-0.9 Bar(-90 kpa)

Minimum atmospheric pressure

0.7bar

Maximum temperature

<145°C

Dimensions

585x438x405mm(Novo Pro 18L)

685x438x405mm(Novo Pro 23L)

Full load weight

45 kg(Novo Pro 18L)

50kg(Novo Pro 23L)

Storage conditions

5~40

Vacuum degree

>-0.8bar

Noise level

<70 DB

Steam filter

Filtration efficiency of particles above 0.3μm is not less than 99.5%

Water quality

Meets EN 13060 ANN.C (thermal conductivity <15MS/CM)

Average water consumption

About 0.25L (minimum), 0.55L (maximum)

Water shortage alarm

Less than 0.5L

Top volume of water tank

Clean water (DWO) about 3.4L

Internal volume of water tank

Waste water (UWO) about 1.7L

 

Procedures

Load Types

Sterilization Type

Temperature ()

Sterilization Time (Minutes)

Drying Time (Minutes)

Solid Instruments

Solid Instruments

S

134/121

10/30

9

Rapid Sterilization

Emergency Sterilization Of Bare Instruments/Rubber

S

134/121

4/20

4

Porous Instruments

Solid And Hollow Loads, Cotton Ball Fabric

B

134/121

5/20

18

Wrapped Instruments

Cotton Ball Fabric, Wrapped Instruments, Hollow Loads

B

134/121

18/30

18

 Product Structure

Pressure steam steriliser consists of sterilisation chamber, heating system, control system and piping system.

1. Sterilisation chamber: made of stainless steel, resistant to high temperature and steam corrosion.

2. Heating system: it adopts external heating method, which is used to heat distilled water and produce water vapour in the sterilizing chamber.

3. Piping system: the piping system consists of several solenoid valves and silicone tubes. It is used to control the air inlet and outlet of the sterilisation chamber.

4. Control system: The heater and solenoid valve are controlled by microcomputer, and the temperature and pressure parameters in the sterilisation room are monitored and controlled in real time by pressure sensor and temperature sensor.

The temperature and pressure parameters in the sterilisation room are monitored in real time by pressure sensors and temperature sensors. The control system is equipped with state detection function, which can react to the abnormal situation in the sterilisation room, interrupt the work process which may be dangerous, and have alarm prompts.

Precautions:

1. Indoor use only

2. Installation of the steriliser should leave at least 10cm spacing around the top of the 20cm, the steriliser cooling and exhaust place can not be closed or blocked

3. Do not put anything on top of the steriliser case to avoid potential danger;

4. Place the steriliser in a well-ventilated environment;

5. The heat dissipation window of the steriliser case should not be blocked by foreign objects;

6. The steriliser should be mounted on a stable workbench, the front end must be higher than the rear end (by adjusting the two front feet).

7. Steriliser peripheral temperature 5-40 ℃, relative humidity ≤ 85%) Air pressure: 70kpa (0.7bar) ~ 106kpa (1.06bar);

8. Do not place any objects in front of the steriliser that dissolve when they see heat, and do not have bottles filled with easily corroded and other liquids around it, so as not to dissipate the heat of the steriliser resulting in a potential hidden - the front of the front do not have objects blocking the front in order to cause the opening of the door is inconvenient. 

Sterilisation Preparation & Selection Of Procedures:

1. Prior to sterilisation, instruments are rinsed completely with clean water to avoid any chemical residues contaminating the steriliser.

2. When instruments are placed on the instrument trays, make sure that they are all placed in the instrument trays, that there is no direct contact between them and that they do not interfere with other instrument trays in the chamber.

3. Sterilised instruments should be placed on the instrument trays with a gap between them to facilitate air circulation in the chamber.

4. The load is appropriate for the selected sterilisation procedure.

5. When working, the door handle must be screwed to the bottom to ensure that the door is closed.

Aborting The Programme:

1. When the sterilisation run is finished or aborted, open the door and beware of hot steam coming out of the pot;

2. When the programme is aborted unexpectedly, the load may not be effectively sterilised repacking the steriliser if necessary;

3. Do not try to force open the door and abort the procedure in the operation, in order to prevent the high temperature and high pressure out of the scalding operator or damage to the equipment, should be in accordance with the requirements of the manual of the operation step by step to abort the procedure;

4. before opening the door, please observe the pressure value on the display or prompt, confirm the safety before opening the door, the pressure value must be less than 10Kpa. when opening the door of the steriliser, please do not get too close to the door to avoid burns.

Payment & Security

Visa Mastercard American Express PayPal Discover

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

All of our products come with free shipping, so please don't worry about shipping.

We have put a lot of focus on making sure the items get delivered to our customers as quickly as possible.

The total time is the sum of the processing time and the shipping time. Processing time = the time between when you place an order and when we ship it; Shipping time = the time between when your order has been shipped and deliveto you;

All products have a 1 day processing time

For most products, processing time is 1 day and shipping time is 7-20 days.
In the United States it usually takes 7-15 business days to receive your order; in other countries it can take up to 15-20 days to receive your order.

For large dental equipment, such as dental chairs, the processing time is 1-3 days and shipping time is usually 30-40 days.

All of this information is described inside the product details, if you would like to confirm a more precise time, please contact us and we will calculate it for you as soon as we receive your message.

Any other question, please contact us at info@istardentalsupply.com

Cancellation:

If you wish to cancel your order before shipment, please contact us within 12 hours of placing your order using the contact form or email info@istardentalsupply.com. If you notify us after 12 hours of placing your order, we may not be able to cancel it.

After we receive your message, we will promptly cancel your order and refund the money to your account within 48 hours.

 

Return & Exchange:

1、Return and exchange terms

To qualify for a return, your merchandise must be unused and in the same condition as when you received it.

(1) Your merchandise must be in its original packaging.

(2) You must notify us of your intention to return the merchandise within 15 days of receiving it.

(3) Returned items must be received within 20 days after the return request form is issued.

Please note: For health and hygiene reasons, we do not accept returns of opened dental handpieces, dental intraoral cameras, dental air polishers, and similar items unless defective.

 

2、Defective Items Purchased Online

If you receive an item you believe to be defective, or if there is an issue with a purchase you made, please contact us via the contact form or email. A member of the Istar team will assist in resolving the issue or provide you with the necessary return forms.

 

3、Return and Exchange Information

If you wish to return or exchange items, please provide the following information to us.

(1) Order number

(2) Proof of payment

(3) Product images

 

4、Return/Exchange Process

Contact us via the contact form or email info@istardentalsupply.com, and we'll respond within 12 hours.

 

Return Shipping Fee

Unless otherwise specified, you are responsible for the cost of returning items to us. We recommend all returns be sent back to us via a tracked service, and if the value of the goods exceeds $50, please use an insured service. We are not liable for any returns lost in transit.

Please Note: All returns for both unwanted or faulty items must be logged via our ticketing system. Unauthorised returns unfortunately will not be processed.

 

Refunds

Once we receive your item, we will inspect it and notify you that we have received your returned item. We will immediately notify you on the status of your refund after inspecting the item. If your return is approved, we will initiate a refund to your credit card (or original method of payment).

You will receive the credit within 3-5 workings days depending on your card issuer's policies.

 

After-Sales Contact Information

Tel: +1 430 422 6876

Email: info@istardentalsupply.com

Note: Please contact us before returning any items, otherwise any returns will be refused.

You may also like