Conforms to European Class B standards, with a wide range of applications
It complies with European EN 13060 sterilisation standard and can meet the strict safety test requirements. The equipment is equipped with three times pulsation vacuum drying function, the vacuum degree can reach -0.9bar (-0.09MPa), the residual humidity after sterilisation of instruments can be controlled at <0.2%, which ensures thorough sterilisation, and is suitable for sterilisation of a variety of types of instruments. Applicable instrument types include packaged, unpackaged, solid, Class A hollow, Class B hollow, porous and internal with piping instruments, is the ideal disinfection choice for medical and laboratory environments.
Intelligent computer control system
Adopting imported 16-bit microprocessor for full computer control, it provides intuitive operation and intelligent management, which makes users comfortable in operation. It is suitable for sterilisation of all kinds of instruments in stomatology, ophthalmology, operating theatres and laboratories. Through intelligent control, the sterilisation process is stable and efficient, while reducing human intervention and improving sterilisation efficiency.
Various safety testing procedures
The autoclave for dental clinic is equipped with Bowie&Dick test (B&D test) and vacuum test procedures to detect the steam penetration force and ensure that the steam can completely penetrate the fine structure of each instrument. The penetration effect under different vacuum conditions is effectively guaranteed to meet the high standard of sterilisation requirements and ensure the reliability of the equipment.
Intelligent digital display and fault detection system
Dental autoclave is equipped with a clear digital display system, real-time display of the operating status of the equipment, so that users can grasp the progress of the machine at any time. Perfect fault detection alarm system allows users to quickly determine the cause of equipment failure, reduce downtime and ensure that the equipment is always in the best condition.
Multiple safety protection design
The dental sterilizer is equipped with double door lock interlock protection to ensure that the door cannot be opened when there is pressure in the sterilisation chamber, preventing the safety hazards caused by misuse. The safety protection design further improves the safety in use, suitable for demanding medical and laboratory scenarios.
Flexible sterilisation data recording function
Support the optional built-in printer, each time the disinfection is completed, the device automatically prints the sterilization process and date records, which is convenient for users to form a complete disinfection file. The data logging function helps medical institutions and laboratories to strictly manage sterilisation records, meet regulatory and certification requirements, and provide stronger traceability for sterilisation management.
Automatic cleaning steam generator
Built-in jet steam generator automatic cleaning function, clean the internal pipeline and steam generator, effectively ensure the uniformity of the temperature and pressure distribution in the pot, and further enhance the thoroughness of disinfection and sterilisation.
Waste water tank full alarm system
Built-in waste water tank full alarm system prevents waste water from recycling and effectively avoids waste water residue in the recycling system, which improves the safety of the sterilisation process and sterilisation effect. The equipment will automatically detect the water level of the waste water tank to avoid equipment failure due to the accumulation of waste water, to ensure that the whole process of sterilisation is hygienic and in line with the sterilisation standards.
Parameter:
Volume |
23L |
18L |
Power |
2000W |
1800W |
Voltage |
AC220V/110V±10% |
AC220V/110V±10% |
Frequency |
50/60Hz±1Hz |
50/60Hz±1Hz |
Dimension |
445*640*395mm |
445*550*395mm |
Inner Size |
Ø249*450mm |
Ø249*355mm |
Package Size |
720*520*500mm |
670*520*500mm |
Weight |
53kg |
48kg |
Precautions:
1. When installing the equipment, do not install the equipment in a position where it is difficult to operate the equipment and the power switch of the equipment.
2. The equipment should be placed in a ventilated environment, 10cm of space should be left around the device, and 20cm at the top for drainage and exhaust.
3. Use of this equipment in dry environments, especially in dry environments where man-made materials (man-made fabrics, carpets, etc.) are present, may cause damaging electrostatic discharges, leading to erroneous conclusions.
4. It is prohibited to use this equipment next to sources of strong radiation (e.g., unshielded RF sources), as this may interfere with the normal operation of the equipment.
5. The equipment must be reliably grounded.
6. When installing the equipment, please install the leakage protection device to prevent safety problems caused by component damage.
7. Water: the equipment comes with a water tank, use to go to the water tank to add water, pay attention to add water when the machine must be switched on, the use of water cups attached to the empty box of 3 cups can be, the amount of water is not enough and the water is full of alarms.
8. The water tank full of water tips appear after the water can not be added.
9. Must use water that meets the requirements.
Working Status Display Table:
No.
|
Digital Display
|
Status Name
|
Statements
|
1
|
Ld
|
Standby
|
In this state, the sterilizer is on standby, waiting for loading
|
2
|
He
|
· Heating state
|
In this state, the sterilizer begins to heat up and pressure up
|
3
|
Display Working Time
|
Sterilized Condition
|
In this state, display working time, countdown
|
4
|
PL
|
Drying Regime
|
In this state, the sterilizer dries the sterilized indoor items
|
5
|
Ed
|
|
End of program indication, in this state can open the door to pick up
|
6
|
Show Fault Code
|
Malfunction
|
Displays each fault code
|